Choosing Stretchers and Patient Transport Chairs
Stretchers and transport chairs are easy to overlook in a budget. They are not high-tech equipment, but they are used on every shift, they carry patients through the busiest parts of the hospital, and a poor choice shows up as staff injuries, slow transfers and broken casters. This guide covers how to choose between stretcher types and chairs, and what to check on the spec sheet.
Stretcher, stretcher chair or transport chair?
- Transport and treatment stretchers carry a patient lying down and double as a treatment surface in the emergency department, PACU or pre-op. Examples include the Stryker Prime Series Zoom 1125, Stryker 1005 transfer stretcher, Hillrom TranStar P8000 and Hill-Rom DuraStar.
- Trauma stretchers such as the Stryker 1020 are built for resuscitation bays, with features for imaging and quick access.
- Procedure stretchers are made for specific work. The Stryker 1089 is built for eye surgery, where head position and access for the surgeon matter.
- Stretcher chairs such as the Stryker 5050 and STERIS Hausted APC move between a chair and a flat position. They suit ambulatory surgery, where the patient can stay on one surface from pre-op to discharge.
- Transport chairs such as the Stryker Prime TC and Staxi chair move seated patients through corridors, lobbies and imaging.
Weight capacity and width
Check two numbers, and check whether the manufacturer means the patient alone or everything on the stretcher. Stryker's spec sheet for the Prime Series gives a safe working load of 700 lb, which covers the patient plus the mattress and accessories. It lists 675 lb as the maximum patient weight. The Prime Series comes in 26 in and 30 in widths. A wider deck is more comfortable for larger patients, but it has to fit through your doors, elevators and bays.
For bariatric transfers, look at a dedicated chair such as the Barton i-700 instead of stretching the capacity of a standard model.
Height range and transfers
Most patient handling injuries happen during lateral transfers and when staff work bent over a low surface. A wide height range lets staff match the stretcher to the bed or table. Stryker gives the Prime Series a low height of 20.75 in for the fifth-wheel and big-wheel models and 23 in for the Zoom model, with a high height of 34 in. Compare these numbers with your beds and imaging tables.
Steering and powered drive
Stretchers steer in different ways:
- Fifth wheel. A center wheel that drops down to help the stretcher track straight on long runs and turn in corridors.
- Big wheel. Larger casters that roll more easily over thresholds.
- Powered drive. Stryker's Zoom drive is a motorized wheel that does most of the pushing. Stryker's manual notes the stretcher can still be pushed by hand if the battery runs out.
Powered drive costs more and needs charging, but it is worth it for long transport routes, heavier patients and departments where staff injuries are a problem.
Intended use
Read the manufacturer's intended-use statement. Stryker describes the Prime Series as stretchers for short-term use in areas such as the emergency department, trauma and PACU, not as a replacement for an inpatient bed. If patients will stay on the stretcher for many hours, look at the mattress, pressure care and any options for long stays.
Transport chairs
Stryker's spec sheet for the Prime TC (model 1460) lists a 500 lb weight capacity, a 21.5 in seat width and a seat height of 21 in. It includes a one-touch central brake, anti-tip wheels, flip-up footrests and a nesting design so several chairs can be stored in a small space. Stryker says the chair can be power-washed, except versions with the padded seat. Those details matter more than they look: chairs that nest save corridor space, and chairs that can be washed are faster to turn around.
Buying refurbished
Most of our stretchers and transport chairs are refurbished. Ask the supplier:
- Which parts were replaced: casters, brakes, hydraulic or electric lift parts, side rails, mattress and IV poles.
- Whether the brake, steer, lift and side rails were tested through their full range.
- For powered models, the battery age and whether the drive and charger were tested.
- The model number and date of manufacture, and whether the manufacturer still supports the model with parts.
- Whether the mattress is included, and its condition. Damaged covers cannot be cleaned properly and should be replaced.
Our refurbished equipment checklist has the general questions to ask.
Frequently asked questions
What is the difference between safe working load and maximum patient weight?
Safe working load is the total the stretcher is rated to carry, including the patient, mattress and accessories. Maximum patient weight is the limit for the patient alone. Stryker lists 700 lb and 675 lb respectively for the Prime Series.
Is a powered stretcher worth it?
It is worth considering for long transport routes, heavier patients and departments with staff injury concerns. For short runs in a small facility, a manual stretcher with a fifth wheel is usually enough.
Can a stretcher chair replace a stretcher?
In ambulatory surgery it often can, because the patient stays on one surface from admission to discharge. For trauma, imaging transfers and patients who cannot sit, you still need a stretcher.
Next steps
Browse stretchers and gurneys and transport chairs, or request a quote with the models, quantity, widths and delivery location you need.